首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Steam plume length diagram for direct contact condensation of steam injected into water
Authors:A de With  
Institution:aSafety and Performance, Thermohydraulica and Fuel Management, Nuclear Research and Consultancy Group, Utrechtseweg 310, P.O. Box 9034, 6800 ES Arnhem, The Netherlands
Abstract:Direct Contact Condensation (DCC) of steam in water occurs when steam is introduced into water. It is a phenomenon of high importance in many industrial applications. An important feature of the DCC is the length of the steam plume. Correlations for a steam plume length presently available are accurate only for limited conditions. In this paper, a new two-dimensional steam plume length diagram is presented capable of predicting length accurately for a wide range of conditions. The diagram is validated against experiments. Furthermore, corrections necessary to adopt the diagram for steam injection into a water flow are discussed in the paper.
Keywords:Steam  Direct contact condensation  Steam plume  Plume length diagram
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏