Abstract: | Based on conduction model and cubic particle model, the relationship between current density and shear yield stress of electrorheological (ER) fluids was calculated and compared with some reported experimental results. The conductivity of the insulating oils is found to have been changed by the mixed particles. Several ways to decrease insulating liquid conductivity and increase the conductivity ratio of ER fluids have been proposed to prepare ER fluids with high shear yield stresses but low current densities. |