首页 | 本学科首页   官方微博 | 高级检索  
     


Improvement of plant parameters of the ROBO gamma irradiation facility due to design modification
Authors:A. Kovacs A. Moussa    I. Othman C. Del Valle Odar    A. Seminario    M. Linares    P. Huamanlazo    J. Aymar  R. Chu
Affiliation:

Institute of Isotopes of the Hungarian Academy of Sciences, H-1525, Budapest, P.O.B. 77., Hungary

Syrian Atomic Energy Commission, Damascus, P.O.B. 6091, Syria

IPEN & Inmune S.A., Lima, Peru

MDS Nordion, P.O.B. 13500, Kanata, Ontario, K2K 1X8, Canada

Abstract:Two industrial scale, “ROBO” type 60Co gamma irradiation facilities have recently been put into operation in Syria and Peru, and the dosimetry commissioning of both plants have been carried out to determine dose distribution within products and to calculate plant parameters such as efficiency, dose uniformity ratio and throughput. There are some design modifications between the two plants in connection with the location of the carriers with respect to the source plaque and also to each other. The effect of these construction modifications on the plant parameters is discussed in the analysis of the dose distribution data measured in the carriers with depth and height among the four irradiation rows on both sides of the source plaque. The plant parameters were also calculated for different product densities using the technical data of the facilities, and the calculated and measured results were compared to each other.
Keywords:Author Keywords: Radiation processing   gamma irradiation facility   dosimetry commissioning   operation parameters
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号