a Institute for Energetic and Nuclear Research, IPEN, CNEN/SP, Department of Nuclear Techniques Application, TE, P.O. Box 11049, CEP 05499-970, São Paulo, Brazil
b Sao Paulo State Sanitation Company, SABESP, Suzano System Division, Brazil
Abstract:
A preliminary study to combine electron beam irradiation process with biological treatment was carried out. Experiments were conducted using samples from a governmental wastewater treatment plant (WTP) that receives about 20% of industrial wastewater, with the objective of destroying the refractory organic pollutants and to obtain a better performance of this plant. Samples from five different steps of WTP were collected and irradiated in the electron beam accelerator in a batch system with 5.0, 10.0 and 20.0 kGy doses. The main results showed a removal of 99% of all organic compound analysed in the industrial receiver unit (IRU) effluent and in the coarse bar screen (CBS) effluent with a 20 kGy dose, and for the medium bar screen (MBS) and primary sedimentation (PS) effluent a 10 kGy dose was sufficient. In the case of final effluent (FE), a dose of 5 kGy removed the remaining organic compounds and dyes present after biological treatment.