首页 | 本学科首页   官方微博 | 高级检索  
     


Measuring Light Field of Light Source with High Directional Resolution Using Mirrored Ball and Pinhole Camera
Authors:Koichi Takase  Norimichi Tsumura  Toshiya Nakaguchi  Yoichi Miyake
Affiliation:(1) Graduate School of Science and Technology, Chiba University, 1-33 Yayoi-cho, Inage-ku Chiba 263-8522, Japan;(2) Research Center for Frontier Medical Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku Chiba 263-8522, Japan
Abstract:This paper presents a method of measuring a light field of a light source with high directional resolution using a mirrored ball and a pinhole camera. The light field describes a spatial and directional distribution of radiances from the light source. The directional distribution is expanded by a reflection on the mirrored ball, and the radiances are measured by a charge-coupled device (CCD) camera with a pinhole lens. The light source is laterally moved by a robot arm to measure the directionally expanded light field, and each pixel on a CCD can obtain the radiances from the light source through the pinhole lens with high directional resolution. The light field is estimated from the pixel value and the position of each pixel using a ray tracing technique. The light field of a krypton lamp was experimentally measured by the proposed method, and the accuracy of the measurement was evaluated against the irradiances measured by a spectro-radiometer at sample points.
Keywords:light field  light source  directional resolution  mirrored ball  pinhole camera  ray tracing
本文献已被 SpringerLink 等数据库收录!