首页 | 本学科首页   官方微博 | 高级检索  
     

Sensitive Method for Enantioseparation of Rivastigmine with Highly Sulfated Cyclodextrin as Chiral Selector by Capillary Electrophoresis
引用本文:王兆彦 许杏祥 胡之德 康经武. Sensitive Method for Enantioseparation of Rivastigmine with Highly Sulfated Cyclodextrin as Chiral Selector by Capillary Electrophoresis[J]. 中国化学, 2006, 24(10): 1384-1387. DOI: 10.1002/cjoc.200690258
作者姓名:王兆彦 许杏祥 胡之德 康经武
作者单位:College of Chemistry and Chemical Engineering Lanzhou University,Lanzhou,Gansu 730000,China Shanghai Institute of Organic Chemistry,Chinese Academy of Sciences,Shanghai 200032,China,Shanghai Institute of Organic Chemistry,Chinese Academy of Sciences,Shanghai 200032,China,College of Chemistry and Chemical Engineering,Lanzhou University,Lanzhou,Gansu 730000,China,College of Chemistry and Chemical Engineering,Lanzhou University,Lanzhou,Gansu 730000,China Shanghai Institute of Organic Chemistry,Chinese Academy of Sciences,Shanghai 200032,China
基金项目:Project-supported by the Bairen Plan Foundation from the Chinese Academy of Sciences.
摘    要:A sensitive method for enantioseparation of a basic drug rivastigmine and determination of its optical impurityby capillary electrophoresis with highly sulfated β-cyclodextrin(HS-β-CD)as the chiral selector is described.Ingeneral,enantioseparation of basic chiral compounds is carried out in acidic condition(pH 2.5)to prevent analytesfrom adsorption on the capillary wall.However,in the case of rivastigmine,the detection sensitivity was too limitedto determine the optical impurity of S-rivastigmine lower than 1% when buffer pH was 2.5.It was found that thedetection sensitivity was improved 1.6 times just by raising the buffer pH value from 2.5 to 5.8.The poor columnefficiency due to the adsorption of the analytes on the capillary wall was resolved by using dynamical coating of thecapillary wall with the linear polyacrylamide solution.The experirnental parameters such as the concentration ofHS-β-CD,buffer pH and buffer ionic strength were optimized,respectively.The method was validated in terms ofrepeatability,linearity,limit of detection(LOD)and limit of quantitation(LOQ).Using the present method,the op-tical purity of nonracemic rivastigmine with the enantiomeric excess(ee)value of 99.14% was determined.

关 键 词:rivastigmine  enantioseparation  capillary electrophoresis  highly sulfated β-cyclodextrin
收稿时间:2006-01-19
修稿时间:2006-01-192006-06-26

Sensitive Method for Enantioseparation of Rivastigmine with Highly Sulfated Cyclodextrin as Chiral Selector by Capillary Electrophoresis
WANG Zhao-Yan, XU Xing-Xiang, HU Zhi-De, KANG Jing-Wu. Sensitive Method for Enantioseparation of Rivastigmine with Highly Sulfated Cyclodextrin as Chiral Selector by Capillary Electrophoresis[J]. Chinese Journal of Chemistry, 2006, 24(10): 1384-1387. DOI: 10.1002/cjoc.200690258
Authors:WANG Zhao-Yan   XU Xing-Xiang   HU Zhi-De   KANG Jing-Wu
Affiliation:1. College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, Gansu 730000, China; 2. Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
Abstract:A sensitive method for enantioseparation of a basic drug rivastigmine and determination of its optical impurity by capillary electrophoresis with highly sulfated β‐cyclodextrin (HS‐β‐CD) as the chiral selector is described. In general, enantioseparation of basic chiral compounds is carried out in acidic condition (pH 2.5) to prevent analytes from adsorption on the capillary wall. However, in the case of rivastigmine, the detection sensitivity was too limited to determine the optical impurity of S‐rivastigmine lower than 1% when buffer pH was 2.5. It was found that the detection sensitivity was improved 1.6 times just by raising the buffer pH value from 2.5 to 5.8. The poor column efficiency due to the adsorption of the analytes on the capillary wall was resolved by using dynamical coating of the capillary wall with the linear polyacrylamide solution. The experimental parameters such as the concentration of HS‐β‐CD, buffer pH and buffer ionic strength were optimized, respectively. The method was validated in terms of repeatability, linearity, limit of detection (LOD) and limit of quantitation (LOQ). Using the present method, the optical purity of nonracemic rivastigmine with the enantiomeric excess (ee) value of 99.14% was determined.
Keywords:rivastigmine  enantioseparation  capillary electrophoresis  highly sulfated β‐cyclodextrin
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏