首页 | 本学科首页   官方微博 | 高级检索  
     检索      

热致梯度折射率对非球面光学系统成像质量的影响
引用本文:姜东旭,孙宝玉,李迎春,林洁琼,王冬雪,王文攀.热致梯度折射率对非球面光学系统成像质量的影响[J].光子学报,2020,49(1):54-61.
作者姓名:姜东旭  孙宝玉  李迎春  林洁琼  王冬雪  王文攀
作者单位:长春工业大学,长春 130012,长春工业大学,长春 130012,长春工业大学,长春 130012,长春工业大学,长春 130012,长春工业大学,长春 130012,中国科学院长春光学精密机械与物理研究所,长春 130033
基金项目:科技部国家重点研究发展计划项目
摘    要:机载相机在上升过程中,由于温度降低和镜头各部分材料的导热率大小不同,镜头部分会产生温度梯度,从而导致非球面光学系统产生梯度折射率.利用有限元分析软件对镜头部分进行瞬态热分析以模拟机载相机上升过程中温度的变化情况,将有限元分析不同时间节点温度分布结果导入编写的折射率梯度系数拟合程序,将所求解的梯度折射率系数通过镜面类型接口在光学软件中建立光学系统模型,利用点列图的弥散斑半径评价不同时间节点梯度折射率对成像质量的影响.结果表明,机载相机刚升入工作高度时温度梯度最大,对成像质量影响也最严重,梯度折射率系数随着温度梯度系数的降低而降低,同时成像质量提高,该结果对光学系统的设计具有指导意义.

关 键 词:梯度折射率  温度梯度  瞬态热分析  非球面光学系统  非线性拟合  成像质量

Effect of Thermally Induced Gradient Index on Imaging Quality of Aspherical Optical System
JIANG Dong-xu,SUN Bao-yu,LI Ying-chun,LIN Jie-qiong,WANG Dong-xue,WANG Wen-pan.Effect of Thermally Induced Gradient Index on Imaging Quality of Aspherical Optical System[J].Acta Photonica Sinica,2020,49(1):54-61.
Authors:JIANG Dong-xu  SUN Bao-yu  LI Ying-chun  LIN Jie-qiong  WANG Dong-xue  WANG Wen-pan
Institution:(Changchun University of Technology,Changchun 130012;Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China)
Abstract:During the ascent of the airborne camera,due to the temperature drop and the thermal conductivity of the material of each part of the lens,the lens portion can have a temperature gradient,which causes the aspherical optical system to produce a gradient index.Using the finite element analysis software to perform transient thermal analysis on the lens part to simulate the temperature change during the ascent of the airborne camera,the finite element analysis of the temperature distribution results of different time nodes was introduced into the prepared refractive index gradient coefficient fitting program,and the solution was solved.The gradient index coefficient established the optical system model in the optical software through the mirror type interface,and use the speckle radius of the dot-column diagram to evaluate the influence of the image quality on the gradient index of the different time nodes.The results show that the temperature gradient of the airborne camera is the highest when it is lifted into the working height,and the influence on the imaging quality is also the most serious.The gradient refractive index coefficient decreases with the decrease of the temperature gradient coefficient,and the imaging quality is improved,which has guiding significance for the optical system design.
Keywords:Gradient index  Temperature gradient  Transient thermal analysis  Aspheric optical system  Nonlinear fitting  Imaging quality
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号