首页 | 本学科首页   官方微博 | 高级检索  
     

基于光纤气泡和纤芯失配的Mach-Zehnder干涉液体折射率传感器
引用本文:李辉栋,傅海威,邵敏,赵娜,乔学光,刘颖刚,李岩,闫旭. 基于光纤气泡和纤芯失配的Mach-Zehnder干涉液体折射率传感器[J]. 物理学报, 2013, 62(21): 214209-214209. DOI: 10.7498/aps.62.214209
作者姓名:李辉栋  傅海威  邵敏  赵娜  乔学光  刘颖刚  李岩  闫旭
作者单位:1. 西安石油大学理学院光电油气测井与检测教育部重点实验室, 西安 710065;2. 西北大学物理系, 西安 710069
摘    要:介绍了一种基于光纤气泡和纤芯失配的Mach-Zehnder干涉液体折射率传感器. 将两根纤芯经过腐蚀的普通单模光纤熔接在一起, 在熔接点处形成一个气泡, 在距气泡20 mm处级联一段20 mm的细芯光纤, 再接入一段单模光纤, 形成单模光纤-气泡-单模光纤-细芯光纤-单模光纤结构的传感器. 气泡与光纤芯径失配处的两个节点起到光纤耦合器的作用, 从而形成光纤Mach-Zehnder干涉仪. 环境液体折射率的变化,将使得传感器透射谱能量发生变化, 通过测量干涉谱波峰峰值能量从而实现对折射率的测量. 并对所制作传感器的折射率响应特性进行了实验研究, 实验结果表明干涉谱波峰峰值能量与环境液体折射率之间存在良好的线性关系, 当环境液体折射率变化范围在1.351–1.402时, 响应灵敏度为143.537 dB/RIU, 线性度0.996. 该传感器在生物化学领域有较好的应用前景.关键词:光纤气泡纤芯失配Mach-Zehnder干涉仪折射率传感

关 键 词:光纤气泡  纤芯失配  Mach-Zehnder干涉仪  折射率传感
收稿时间:2013-05-15

In-fiber Mach-Zehnder interferometer based on fiber core etched air-bubble and core diameter mismatch for liquid refractive index sensing
Li Hui-Dong,Fu Hai-Wei,Shao Min,Zhao Na,Qiao Xue-Guang,Liu Ying-Gang,Li Yan,Yan Xu. In-fiber Mach-Zehnder interferometer based on fiber core etched air-bubble and core diameter mismatch for liquid refractive index sensing[J]. Acta Physica Sinica, 2013, 62(21): 214209-214209. DOI: 10.7498/aps.62.214209
Authors:Li Hui-Dong  Fu Hai-Wei  Shao Min  Zhao Na  Qiao Xue-Guang  Liu Ying-Gang  Li Yan  Yan Xu
Abstract:A kind of optical fiber liquid refractive index sensor is proposed based on fiber core etched air-bubble and core diameter mismatched in-fiber Mach-Zehnder interferometer. A core etched standard single-mode fiber is spliced to another core etched standard single-mode fiber (SMF) to form an air bubble at the connecting point, and a 20 mm thinned fiber is cascaded (TCF) by fusion splicing method, which is 20 mm apart from the bubble, then a leading-mode fiber is spliced to the thinned fiber to form a structure of SMF-(air-bubble)-SMF-TCF-SMF in-fiber Mach-Zehnder interferometer liquid refractive index sensor. The air-bubble and the two fiber core diameter mismatched points serve as optical couplers for modes conversion. The transmission spectrum of sensor is studied by experiment. Results shows that the peak power changes with respect to surrounding refractive index with good linearity. The sensitivity of the sensor is 142.537 dB/RIU in the range of 1.351–1.402 with linearity of 0.996, making it a good candidate for bio-chemical measurements.
Keywords:in-fiber air bubblecore diameter mismatchin-fiber Mach-Zehnder interferometerrefractive index sensing
Keywords:in-fiber air bubble  core diameter mismatch  in-fiber Mach-Zehnder interferometer  refractive index sensing
点击此处可从《物理学报》浏览原始摘要信息
点击此处可从《物理学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号