摘 要: | 本文从理论上阐述了采用最大偏向角法测量光学玻璃常数的方法。推导出计算原理公式,并分析了色散的测量误差,其测试精度为±1.0×10~(-8)。其次,简要地讲述了样品的制备要求和测试方法。
|
Measuring Optical Constant with Method of Maximum Angle of Deviation |
| |
Abstract: | The paper elal rates the method that optical constant is measured withmaximum angle of deviation on thoery. The calculating formula is infered,and the error limit for dispersion measurement is analysied. The error limitfor dispersion measurement is ±1.0×10~(-6). In the other, the specimen and themearsuring method is discrabed simply. |
| |