首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Precision in differential field-flow fractionation: a chemometric study
Authors:Bregola Letizia  Contado Catia  Martin Michel  Pasti Luisa  Dondi Francesco
Institution:Department of Chemistry, Ferrara, Italy.
Abstract:In the present paper, the capabilities of differential field-flow fractionation, i. e., the determination of an incremental quantity of a colloidal species, e. g., an uptake adsorbed mass, determined by the joint use of two independent FFF measurements, over a species and the same modified species respectively, are considered. The different error types, those related to the retention time determinations and those coming from the operating parameter fluctuations were considered. The different components were computed with reference to SdFFF determinations of bare polystyrene (PS) submicronic particles and the same PS particles covered by IgG. Comparison was made between theoretically computed precision and experiments. The error coming from the experimental measurement of retention times was identified to be the main source of errors. Accordingly, it was possible to make explicit the detection limits and the confidence intervals of the adsorbed mass uptake, as a function of experimental quantities such as the retention ratio, the detector calibration ratio, the injected quantity, the baseline noise, and the void time relative error. An experimentally determined and theoretically foreseen dependence of both the experimental detection and confidence limits (approximately +/- 10(-17) g) on the square root of the injected concentration, for constant injected volume, was found.
Keywords:Differential field‐flow fractionation  Error on retention time  Immunoglobulin G  Mass uptake  Precision
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号