Rapid method for the photometric determination of manganese in ores and alloys
Authors:P Kanta Rao and G S Chowdhury
Institution:(1) Regional Research Laboratory, Bhubaneswar, India;(2) Present address: Institut für Techn. Chemie der Technischen Universität Berlin, Straße des 17. Juni 122-128, 1000 Berlin 2
Abstract:Summary A procedure for the rapid photometric determination of manganese in the range of 4–24 mg/50 ml, is based on the oxidation of manganese(II) to manganese(III) by excess potassium dichromate in a medium of 8.0 to 9.0 M phosphoric acid at room temperature. Interferences are few when compared to the methods currently available. The method can be successfully employed for the estimation of manganese in ores and alloys and the results obtained compare favourably with standard methods. The method is therefore recommended for adaption for rapid routine analysis.
Schnelle Methode zur photometrischen Bestimmung von Mangan in Erzen und Legierungen
Zusammenfassung Ein Verfahren zur raschen Bestimmung von Mangan im Bereich von 4–24 mg/50 ml wird beschrieben. Es beruht auf der quantitativen Oxydation von Mn(II) zu Mn(III) mit Dichromat in 8,0–9,0 M phosphorsaurer Lösung bei Raumtemperatur. Die Störmöglichkeiten sind geringer als bei sonst üblichen Methoden. Das Verfahren wurde mit Erfolg zur Manganbestimmung in Erzen und Legierungen angewendet und gute Übereinstimmung mit Standardmethoden erzielt. Es wird für die schnelle Routineanalyse empfohlen.