Isocratic determination of arachidonic acid 5-lipoxygenase products in human neutrophils by high-performance liquid chromatography |
| |
Authors: | H Mita Y Yui H Yasueda T Shida |
| |
Affiliation: | Clinical Research Centre for Rheumato-Allergology, National Sagamihara Hospital, Kanagawa, Japan. |
| |
Abstract: | A high-performance liquid chromatographic method was developed to determine arachidonic 5-lipoxygenase products in calcium ionophore-stimulated neutrophils. This procedure allows the simultaneous measurement of leukotriene B4 (LTB4) and its omega-oxidation products without using a gradient elution system. 20-Carboxy-LTB4, 20-hydroxy-LTB4, 6-trans-LTB4, 12-epi-6-trans-LTB4, LTB4 and 5s,12s-dihydroxyeicosatetraenoic acid can be separated and quantitated by reversed-phase chromatography using isocratic elution. The generation and degradation of 5-lipoxygenase products by human neutrophils following stimulation with calcium ionophore have been examined by this method. |
| |
Keywords: | |
|
|