首页 | 本学科首页   官方微博 | 高级检索  
     检索      

In Vivo Degradation Behavior of Porous Composite Scaffolds of Poly(lactide-co-glycolide) and Nano-hydroxyapatite Surface Grafted with Poly(L-lactide)
引用本文:刘建国,章培标.In Vivo Degradation Behavior of Porous Composite Scaffolds of Poly(lactide-co-glycolide) and Nano-hydroxyapatite Surface Grafted with Poly(L-lactide)[J].高分子科学,2014,32(6):805-816.
作者姓名:刘建国  章培标
作者单位:[1]First Hospital, Jilin University, Changchun 130021, China [2]Key Laboratory of Polymer Ecobiomaterials, Changchun Institute of Applied Chemistry, Graduate School of Chinese Academy of Sciences, Chinese Academy of Sciences, Changchun 130022, China
基金项目:This work was financially supported by the National Natural Science Foundation of China (Nos. 51273081, 51103149 and 51273195), the Project of Intemational Cooperation from the Ministry of Science and Technology of China (No.S2013GR04340), and the Major Project of Science and Technology of Jilin Province (20130201005GX).
摘    要:The biodegradable porous composite scaffold, composed of poly(lactide-co-glycolide)(PLGA) and hydroxyapatite nanoparticles(n-HAP) surface-grafted with poly(L-lactide)(PLLA)(g-HAP)(g-HAP/PLGA), was fabricated using the solvent casting/particulate leaching method, and its in vivo degradation behavior was investigated by the intramuscular implantation in rabbits. The composite of un-grafted n-HAP/PLGA and neat PLGA were used as controls. The scaffolds had interconnected pore structures with average pore sizes between 137 μm and 148 μm and porosities between 83% and 86%. There was no significant difference in the pore size and porosity among the three scaffolds. Compared with n-HAP/PLGA, the thermo-degradation temperature(Tc) of g-HAP/PLGA decreased while its glass transition temperature(Tg) increased. The weight change, grey value analysis of radiographs and SEM observation showed that the composite scaffolds of g-HAP/PLGA and n-HAP/PLGA showed slower degradation and higher mineralization than the pure PLGA scaffold after the intramuscular implantation. The rapid degradation of PLGA, g-HAP/PLGA and n-HAP/PLGA occurred at 8–12 weeks, 12–16 weeks and 16–20 weeks, respectively. Compared with n-HAP/PLGA, g-HAP/PLGA showed an improved absorption and biomineralization property mostly because of its improved distribution of HAP nanoparticles. The levels of both calcium and phosphorous in serum and urine could be affected to some extent at 3–4 weeks after the implantation of g-HAP/PLGA, but the biochemical detection of serum AST, ALT, ALP, and GGT as well as BUN and CRE showed no obvious influence on the functions of liver and kidney.

关 键 词:纳米羟基磷灰石  支架材料  降解行为  表面接枝  L-乳酸  复合  多孔  体内

In vivo degradation behavior of porous composite scaffolds of poly(lactide-co-glycolide) and nano-hydroxyapatite surface grafted with poly(L-lactide)
Yu-feng Tang,Jian-guo Liu,Zong-liang Wang,Yu Wang,Li-guo Cui,Pei-biao Zhang,Xue-si Chen.In vivo degradation behavior of porous composite scaffolds of poly(lactide-co-glycolide) and nano-hydroxyapatite surface grafted with poly(L-lactide)[J].Chinese Journal of Polymer Science,2014,32(6):805-816.
Authors:Yu-feng Tang  Jian-guo Liu  Zong-liang Wang  Yu Wang  Li-guo Cui  Pei-biao Zhang  Xue-si Chen
Institution:1. First Hospital, Jilin University, Changchun, 130021, China
2. Key Laboratory of Polymer Ecobiomaterials, Changchun Institute of Applied Chemistry, Graduate School of Chinese Academy of Sciences, Chinese Academy of Sciences, Changchun, 130022, China
Abstract:The biodegradable porous composite scaffold, composed of poly(lactide-co-glycolide) (PLGA) and hydroxyapatite nanoparticles (n-HAP) surface-grafted with poly(L-lactide) (PLLA) (g-HAP) (g-HAP/PLGA), was fabricated using the solvent casting/particulate leaching method, and its in vivo degradation behavior was investigated by the intramuscular implantation in rabbits. The composite of un-grafted n-HAP/PLGA and neat PLGA were used as controls. The scaffolds had interconnected pore structures with average pore sizes between 137 μm and 148 μm and porosities between 83% and 86%. There was no significant difference in the pore size and porosity among the three scaffolds. Compared with n-HAP/PLGA, the thermo-degradation temperature (T c) of g-HAP/PLGA decreased while its glass transition temperature (T g) increased. The weight change, grey value analysis of radiographs and SEM observation showed that the composite scaffolds of g-HAP/PLGA and n-HAP/PLGA showed slower degradation and higher mineralization than the pure PLGA scaffold after the intramuscular implantation. The rapid degradation of PLGA, g-HAP/PLGA and n-HAP/PLGA occurred at 8–12 weeks, 12–16 weeks and 16–20 weeks, respectively. Compared with n-HAP/PLGA, g-HAP/PLGA showed an improved absorption and biomineralization property mostly because of its improved distribution of HAP nanoparticles. The levels of both calcium and phosphorous in serum and urine could be affected to some extent at 3–4 weeks after the implantation of g-HAP/PLGA, but the biochemical detection of serum AST, ALT, ALP, and GGT as well as BUN and CRE showed no obvious influence on the functions of liver and kidney.
Keywords:Nanocomposite  Surface modification  Absorption  Biomineralization  Biochemical detection  
本文献已被 CNKI 维普 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号