首页 | 本学科首页   官方微博 | 高级检索  
     


Transferrin immunoextraction for determination of carbohydrate‐deficient transferrin in human serum by capillary zone electrophoresis
Authors:Jitka Caslavska  Jeannine Joneli  Ursula Wanzenried  Jeannette Schiess  Wolfgang Thormann
Affiliation:Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, , Bern, Switzerland
Abstract:CZE‐based assays for carbohydrate‐deficient transferrin (CDT) in which serum is mixed with an Fe(III) ion‐containing solution prior to analysis are effective approaches for the determination of CDT in patient samples. Sera of patients with progressed diseases, however, are prone to interferences comigrating with transferrin (Tf) that prevent the proper determination of CDT by CZE in these samples. The need of a simple and economic approach to immunoextract Tf from human serum prompted us to investigate the use of a laboratory‐made anti‐Tf spin column containing polyclonal rabbit anti‐human Tf antibodies linked to Sepharose 4 Fast Flow beads. This article reports extraction column manufacturing and column characterization with sera having normal and elevated CDT levels. The developed procedure was applied to a number of relevant hepatology and dialysis patient samples and could thereby be shown to represent an effective method for extraction and concentration of all Tf isoforms. Furthermore, lipemic sera were delipidated using a mixture of diisopropyl ether and butanol prior to immunoextraction. CDT could unambiguously be determined in all pretreated samples.
Keywords:Carbohydrate‐deficient transferrin  Dialysis  Hepatology  Immunoextraction
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号