首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Evaluation of nonlinear chromatographic performance by frontal analysis using a simple multi-plate mathematical model
Authors:Hao Weiqiang  Wang Junde
Institution:Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116012, PR China.
Abstract:A multi-plate (MP) mathematical model was proposed by frontal analysis to evaluate nonlinear chromatographic performance. One of its advantages is that the parameters may be easily calculated from experimental data. Moreover, there is a good correlation between it and the equilibrium-dispersive (E-D) or Thomas models. This shows that it can well accommodate both types of band broadening that is comprised of either diffusion-dominated processes or kinetic sorption processes. The MP model can well describe experimental breakthrough curves that were obtained from membrane affinity chromatography and column reversed-phase liquid chromatography. Furthermore, the coefficients of mass transfer may be calculated according to the relationship between the MP model and the E-D or Thomas models.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号