Highly specific and sensitive liquid chromatography-tandem mass spectrometry method for the determination of 3-desmethylthiocolchicine in human plasma as analyte for the assessment of bioequivalence after oral administration of thiocolchicoside |
| |
Authors: | Sutherland F C W Smit M J Herbst L Els J Hundt H K L Swart K J Hundt A F |
| |
Affiliation: | Farmovs-Parexel Clinical Research Organisation, Brandhof, Bloemfontein, South Africa. chris.sutherland@farmovs-parexel.com |
| |
Abstract: | A sensitive method for the determination of 3-desmethylthiocolchicine in plasma was developed, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The plasma samples were extracted with ethyl acetate and separated on a Phenomenex Luna C18(2) 5 microm, 150x2 mm column with a mobile phase consisting of acetonitrile-0.005% formic acid (350:650, v/v) at a flow rate of 0.35 ml/min. Detection was achieved by an Applied Biosystems API 2000 mass spectrometer (LC-MS-MS) set at unit resolution in the multiple reaction monitoring mode. TurbolonSpray ionisation was used for ion production. The mean recovery for 3-desmethylthiocolchicine was 70%, with a lower limit of quantification set at 0.39 ng/ml. The increased selectivity of mass spectrometric (MS-MS) detection allowed us to distinguish between thiocolchicoside and its primary metabolite 3-desmethylthiocolchicine in human plasma, thereby giving more insight about the pharmacokinetics of the drug in humans. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|