首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Comparison of direct sampling and emulsion analysis using a filter furnace for the determination of lead in crude oil by graphite furnace atomic absorption spectrometry
Authors:Isabel CF Damin  Morgana B Dessuy  Tamara S Castilhos  Márcia M Silva  Maria Goreti R Vale  Bernhard Welz  Dmitri A Katskov
Institution:1. Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre — RS, Brazil;2. Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis — SC, Brazil;3. Tshwane University of Technology (TUT), Faculty of Science, Chemistry Department, Pretoria 0001, South Africa
Abstract:The determination of trace elements in crude oil is difficult due to the complex nature of the sample and the various different chemical forms in which the metals can occur. The advantage of graphite furnace atomic absorption spectrometry is that only a minimum of sample pretreatment is required. In this work two techniques have been compared to establish a fast and reliable method for lead determination in crude oil. In the first one the crude oil samples were weighed directly onto solid sampling (SS) platforms and introduced into the graphite tube for analysis. In the second one the samples were prepared as oil-in-water emulsions and analyzed in a filter furnace (FF). Twenty μL of a mixture of 0.5 mg L− 1 Pd + 0.3 mg L− 1 Mg + Triton X-100 has been used as the modifier, and calibration against aqueous solutions has been used for both methods. The sensitivity obtained with the FF was more than a factor of two better than that with SS; however, as a larger sample mass could be introduced in the latter case, so that the limits of detection for both techniques were 0.004 mg kg− 1. Seven crude oil samples were analyzed using the two procedures, and all results were in agreement at a 95% confidence level using a paired Student's t-test. For validation purposes, three crude oil samples have been mineralized using an open-vessel acid digestion, and the results were in agreement with those found with direct sampling and with emulsion sampling using FF according to ANOVA test. Both methods are simple, fast and reliable, being appropriated for routine analysis; however, the direct method using SS technology should be preferred because of its simplicity, speed and commercial availability.
Keywords:Lead  Crude oil  Filter furnace  Direct sampling  Graphite furnace atomic absorption spectrometry
本文献已被 ScienceDirect 等数据库收录!