Measurement of temperature and temperature profile of an axisymmetric gaseous flames using Lau phase interferometer with linear gratings
Authors:Madhuri Thakur  A L Vyas  Chandra Shakher  
Institution:Laser Application and Holography Laboratory, Instrument Design and Development Centre, Indian Institute of Technology, Delhi, New Delhi - 110 016, India
Abstract:In this paper we have investigated the utility of Lau phase interferometer with linear gratings and white light source to measure temperature and temperature profile of an axisymmetric flame. The temperature measured using Lau phase interferometer is in good agreement with the temperature measured with thermocouple and datalogger. Details of theoretical analysis and experimental investigation are presented.
Keywords:Refractive index  Temperature profile  Lau phase interferometer