首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Metrological concept for comparable measurement results under the European water framework directive: demonstration of its applicability in elemental analysis
Authors:Detlef Schiel  Olaf Rienitz  Reinhard J?hrling  Bernd G??ttler  Ralf Matschat  Holger Scharf  J??rgen Birkhahn  Guillaume Labarraque  Paola Fisicaro  Ulrich Borchers  David Schwesig
Institution:1. Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Germany
2. BAM Bundesanstalt für Materialforschung und -prüfung, Berlin, Germany
3. Laboratoire National de Métrologie et d’Essais (LNE), Paris, France
4. IWW Water Centre, Mülheim, Germany
Abstract:Within the scope of a project of the “European Association of National Metrology Institutes??(EURAMET), a European metrological dissemination system (network) providing traceable reference values assigned to matrix materials for validation purposes is described and put to the test. It enables testing laboratories (TL) to obtain comparable results for measurements under the “EU Water Framework Directive 2000/60/EC??(WFD) and thus, to comply with a core requirement of this very directive. The dissemination system is characterized by the fact that it is available to all laboratories throughout Europe which intend to perform measurements in the context of the WFD and that it can ensure sustainable metrological traceability to the International System of Units (SI) as a reference point for the measurement results. This dissemination system is set up in a hierarchical manner and links up the level of the national metrology institutes (NMI) with that of the TLs via an intermediate level of calibration laboratories (CL) by comparison measurements. The CLs are expert laboratories with respect to the measurement of the analytes considered here (within the project, the CLs are called potential calibration laboratories (PCL)) and are additionally involved in the organization of comparison measurements within the scope of regional quality assurance (QA) systems. Three comparison measurements have been performed to support the approach. A total of about 130 laboratories participated in this exercise with the focus on the measurement of the priority substances Pb, Cd, Hg, and Ni defined in the WFD. The elemental concentrations in the water samples roughly corresponded to one of the established environmental quality standards (EQS), the annual average concentration (AA-EQS), which is defined in the daughter Directive 2008/105/EC of the WFD. It turned out that a significant number of TLs still need to improve their measurement methods in order to be able to fulfill the minimum requirements of the WFD, in particular, with regard to the elements Cd and Hg probably due to their low EQS values. Furthermore, it became obvious that the hierarchical dissemination system suggested here actually corresponds to the measuring capabilities of the three participating groups (NMIs, PCLs, and TLs).
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号