首页 | 本学科首页   官方微博 | 高级检索  
     

高效液相色谱法同时测定牙膏及漱口水中的23种致癌染料
引用本文:汤娟,费晓庆,富薇,周佳,丁友超,钱凯,董绍伟,曹丽华. 高效液相色谱法同时测定牙膏及漱口水中的23种致癌染料[J]. 分析测试学报, 2021, 40(3): 356-362
作者姓名:汤娟  费晓庆  富薇  周佳  丁友超  钱凯  董绍伟  曹丽华
作者单位:1.南京海关工业产品检测中心,江苏南京210019;2.南京海关动植物与食品检测中心,江苏南京210019;3.中国合格评定国家认可中心,北京100062;4.南京金检检验有限公司,江苏南京210019
基金项目:国家重点研发计划项目(2018YFF0214803);南京海关科研项目(2019KJ25,2019KJ28)
摘    要:建立了同时测定牙膏和漱口水中23种致癌染料的高效液相色谱(HPLC)检测方法.漱口水样品直接以乙醇溶解稀释,牙膏样品烘干后以乙醇超声提取.采用ZORBAX Eclipse XDB-Phenyl(150 mum x 4.6 mm x 5 pm)色谱柱进行分离,以2.5 mmol/L磷酸二氢四丁基铵水溶液(pH7.5)和甲...

关 键 词:高效液相色谱  致癌染料  牙膏  漱口水

Simultaneous Determination of 23 Carcinogenic Dyes in Toothpaste and Mouthwash by High Performance Liquid Chromatography
TANG Juan,FEI Xiao-qing,FU Wei,ZHOU Ji,DING You-chao,QIAN Kai,DONG Shao-wei,CAO Li-hua. Simultaneous Determination of 23 Carcinogenic Dyes in Toothpaste and Mouthwash by High Performance Liquid Chromatography[J]. Journal of Instrumental Analysis, 2021, 40(3): 356-362
Authors:TANG Juan  FEI Xiao-qing  FU Wei  ZHOU Ji  DING You-chao  QIAN Kai  DONG Shao-wei  CAO Li-hua
Affiliation:1.Industrial Products Testing Center,Nanjing Customs,Nanjing210019,China;2.Animal,Plant and Food Inspection Center,Nanjing Customs,Nanjing210019,China;3.China National Accreditation Service for Conformity Assessment,Beijing100062,China;4.Nanjing Jinjian Inspection Co.,Ltd.,Nanjing210019,China
Abstract:A high performance liquid chromatographic(HPLC)method with innovative sample pretreatment was developed for the simultaneous determination of 23 carcinogenic dyes in toothpaste and mouthwash.The mouthwash sample was directly dissolved and diluted by ethanol.After mixed by vortex with quartz sand,the toothpaste sample was vacuum-dried at 75℃,then ultrasonically extracted with ethanol at 50℃for 30 min.The separation of 23 target analytes was performed on a ZORBAX Eclipse XDB-Phenyl column(150 mm×4.6 mm×5μm)by gradient elution with 2.5 mmol/L tetrabutylammonium phosphate(pH 7.5)and methanol-acetonitrile(50∶50,by volume)as mobile phases.The detection wavelengths for diode array detector(DAD)were 400 nm,500 nm and 600 nm,respectively.Quantitative analysis was carried out by external standard method.Results showed that the chromatographic separation for 23 carcinogenic compounds was achieved within 32 minutes.There were good linear relationships for 23 target analytes in the corresponding concentration ranges with correlation coefficients(r2)not less than 0.9991.The detection limits(LOD)and quantitation limits(LOQ)were in the ranges of 0.06-0.66 mg/L and 0.18-1.98 mg/L,respectively.The average recoveries for 23 carcinogenic dyes in negative toothpaste and mouthwash at three spiked levels were in the ranges of 91.2%-104%and 92.0%-103%,with their relative standard deviations(RSD,n=6)of 2.5%-5.8%and 2.3%-5.5%,respectively.239 toothpaste and 88 mouthwash samples were detected by this method,and basic violet 3 was detected in a toothpaste sample.With the advantages of high sensitivity,good precision and satisfactory accuracy,the method is suitable for the quantitative analysis of 23 carcinogenic dyes in all kinds of toothpaste and mouthwash,and provides a good strategy reference for the quality and safety monitoring of toothpaste and mouthwash.
Keywords:high performance liquid chromatography  carcinogenic dye  toothpaste  mouthwash
本文献已被 维普 等数据库收录!
点击此处可从《分析测试学报》浏览原始摘要信息
点击此处可从《分析测试学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号