首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Improved determination of gaseous divalent mercury in ambient air using KCl coated denuders
Authors:Xinbin Feng  J Sommar  K Gårdfeldt  O Lindqvist
Institution:Inorganic Chemistry, Department of Chemistry, G?teborg University, S 412 96 G?teborg, Sweden e-mail: feng@inoc.chalmers.se, SE
Abstract:An improved method for the determination of gaseous divalent mercury (GDM) in ambient air using KCl coated denuders has been developed and tested. GDM collected in the KCl coated denuders can be quantitatively desorbed at 450?°C in 10 min. After being complete thermally reduced to Hg0 at 900?°C, all mercury released from the denuder is pre-concentrated on the analytical Au trap, and detected by cold vapor atomic fluorescence spectrometry (CVAFS). The absolute detection limit of the method is less than 3 pg. Preliminary data of GDM concentration in ambient air from different sampling stations show that GDM concentrations in the urban air of Göteborg are much higher than in rural air (Rörvik and Sasetta), which indicates the anthropogenic origin of GDM.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号