首页 | 本学科首页   官方微博 | 高级检索  
     


Bulk analysis by IR laser ablation inductively coupled plasma atomic emission spectrometry
Authors:Michel Hemmerlin  Dumont Somas  Cendrine Dubuisson  Fabrice Loisy  Emmanuelle Poussel  J.-M. Mermet
Affiliation:IRSID, Voie romaine, BP 320, F-57214 Maiziéres les Metz Cedex, France, FR
Laboratoire des Sciences Analytiques, Bat. 308, Université Claude Bernard-Lyon l, F-69622 Villeurbanne Cedex, France, FR
Abstract:Two laser ablation systems dedicated to bulk analysis were evaluated for steel and PVC samples, using inductively coupled plasma atomic emission spectrometry detection. These systems were characterized by the use of a Nd:YAG laser operating at 1064 nm, the absence of observation device and a large laser spot size. The 1064 nm wavelength was selected to avoid the use of frequency-multiplying optics, and to be less critical to the sampling position. Calibration graphs and limits of detection are given for both types of materials. LODs were in the range 3–120 μg/g for steel, and in the range 0.07–15 μg/g for PVC. In the case of steel samples, similar calibration graph slopes were obtained between polished and unpolished samples.
Keywords:
本文献已被 SpringerLink 等数据库收录!