Abstract:The chemical oscillation chronoamperometry was firstly set up as a new analytical method. The electrocatalysis of bromide with various poly(3-alkylthiophene) modified electrodes was studied and compared. This modified electrode was successfully applied to the chemical oscillation system laniline-sulfuric acid-potassium hromate' for chronoaperometric sthdy. It was found that the logarithm of the oscillation perlod has a linear relationship with the concentraltion of aniline (r=0. 9985 ). This method was applied to the determination of aniline in waste water with satisfactory results.