Non-invasive measurement of void fraction and liquid temperature in microchannel flow boiling |
| |
Authors: | David Fogg Milnes David Kenneth Goodson |
| |
Affiliation: | (1) Creare Inc.,16 Great Hollow Rd, Hanover, NH 03755, USA;(2) Department of Mechanical Engineering, Stanford University, Building 530, Room 224, Stanford, CA 94305-3030, USA |
| |
Abstract: | Past thermometry research for two-phase microfluidic systems made much progress regarding wall temperature distributions, yet the direct measurement of fluid temperature has received little attention. This paper uses a non-invasive two-dye/two-color fluorescent technique to capture fluid temperature along with local liquid fraction in a two-phase microflow generated by injecting air into a heated microchannel. The fluorescent emission of Rhodamine 110 and Rhodamine B, measured with photodiodes, is used to obtain local liquid temperature (±3°C) and void fraction (±2% full-scale) over a temperature range from 45 to 100°C. Arrays of these sensors can significantly expand the set of measurable flow parameters to include bubble/slug frequency, size, velocity, and growth rates in addition to mapping the local liquid temperature and void fraction. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|