首页 | 本学科首页   官方微博 | 高级检索  
     

质子转移反应质谱动态测量苯系物的亨利常数
引用本文:李建权,沈成银,王鸿梅,韩海燕,郑培超,徐国华,江海河,储焰南. 质子转移反应质谱动态测量苯系物的亨利常数[J]. 物理化学学报, 2008, 24(4): 705-708. DOI: 10.3866/PKU.WHXB20080428
作者姓名:李建权  沈成银  王鸿梅  韩海燕  郑培超  徐国华  江海河  储焰南
作者单位:Laboratory of Environment Spectroscopy, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, P. R. China; Key Laboratory of Environmental Optics & Technology, Chinese Academy of Sciences, Hefei 230031, P. R. China
基金项目:国家自然科学基金 , 中国科学院仪器研制与改造项目 , 安徽省优秀青年科技基金 , 安徽省合肥市物质科学研究院院长基金
摘    要:采用动态气体提取方法, 使用自行研制的质子转移反应质谱(PTR-MS)装置, 研究了挥发性苯系物亨利常数的测量方法. 考察了苯在提取气体与水溶液中达到平衡需要的液面高度, 通过25 ℃条件下苯的亨利常数测量验证了动态气体提取方法结合质子转移反应质谱测量亨利常数的有效性, 报告了11种苯系物的亨利常数测量结果. 与常规的亨利常数测量方法相比, 本方法具有简单、快速、人为干扰少等优点.

关 键 词:亨利常数  质子转移反应质谱  化学电离  挥发性有机物  在线监测  
收稿时间:2007-10-17
修稿时间:2007-10-17

Dynamic Measurements of Henry's Law Constant of Aromatic Compounds Using Proton Transfer Reaction Mass Spectrometry
LI Jian-Quan,SHEN Cheng-Yin,WANG Hong-Mei,HAN Hai-Yan,ZHENG Pei-Chao,XU Guo-Hua,JIANG Han-He,CHU Yan-Nan. Dynamic Measurements of Henry's Law Constant of Aromatic Compounds Using Proton Transfer Reaction Mass Spectrometry[J]. Acta Physico-Chimica Sinica, 2008, 24(4): 705-708. DOI: 10.3866/PKU.WHXB20080428
Authors:LI Jian-Quan  SHEN Cheng-Yin  WANG Hong-Mei  HAN Hai-Yan  ZHENG Pei-Chao  XU Guo-Hua  JIANG Han-He  CHU Yan-Nan
Affiliation:Laboratory of Environment Spectroscopy, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, P. R. China; Key Laboratory of Environmental Optics & Technology, Chinese Academy of Sciences, Hefei 230031, P. R. China
Abstract:Henry’s lawconstants (HLC) of volatile aromatic compounds were determined using a dynamics approach by coupling a stripping cell directly to a homemade proton transfer reaction mass spectrometry (PTR-MS). The intensity of C6H6H+ ion dependence on liquid height of benzene solution was explored in order to ensure the equilibrium of aromatic compound components between the gas-bubbles and water. The HLC of benzene measured at 25 ℃ is in agreement with the reported value in literature, showing that this method is valid. HLC values were presented for benzene, toluene, ethylbenzene, chlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, 1,4-dichlorobenzene, 1,2-dimethylbenzene, 1,3-dimethylbenzene, 1,4-dimethylbenzene, and 1,2,4-trimethylbenzene. Compared to the conventional techniques, the dynamics extraction combination with PTR-MS is simple, fast, and less prone to artifacts in the HLC measurement.
Keywords:Henry’s law constant  Proton transfer reaction mass spectrometry  Chemical ionization  Volatile organic compounds  On-line monitoring
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《物理化学学报》浏览原始摘要信息
点击此处可从《物理化学学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号