首页 | 本学科首页   官方微博 | 高级检索  
     


2D LC Separation and Determination of Bradykinin in Rat Muscle Tissue Dialysate with On-Line SPE-HILIC-SPE-RP-MS
Authors:Steven Ray Wilson  Mikolai Jankowski  Milaim Pepaj  Albena Mihailova  Fernando Boix  Gabriel Vivo Truyols  Elsa Lundanes  Tyge Greibrokk
Affiliation:(1) Department of Chemistry, University of Oslo, P.O. Box 1033, Blindern, 0315 Oslo, Norway;(2) Norwegian Institute of Public Health, Postboks 4404, Nydalen, 0403 Oslo, Norway;(3) Polymer-analysis Group, Faculty of Science, University of Amsterdam, Nieuwe Achtergracht 166, 1018 WV Amsterdam, The Netherlands
Abstract:A 2D liquid chromatography (LC) system using hydrophilic interaction chromatography (HILIC) and reversed phase columns has been employed for comprehensive (LC × LC) separation of rat muscle tissue micro-dialysate. Incorporation of an on-line reverse-phase solid phase extraction (SPE) enrichment column in front of the first dimension enabled aqueous samples with high salt concentrations to be injected directly without compromising the chromatographic performance of the HILIC column. Since the SPE enrichment column allowed injection of large sample volumes (e.g. 450 μL), a capillary HILIC column (inner diameter 0.3 mm) could be employed instead of a larger column which is often used in the first dimension to load sufficient amounts of sample. The two chromatographic dimensions were connected using a column selector system with 18, 1.0 mm I.D. C18 “transition” SPE columns. A PLRP C18 column was used in the second dimension. The 2D LC system’s performance was evaluated with a tryptic digest mixture of three model proteins. Good trapping accuracy (HILIC→transition SPE→RP recovery >95%) and repeatability (within-and between day retention time RSDs of first and second dimension chromatography >1%) was achieved. A dialysis sample of rat muscle tissue was separated with the 2D system, revealing complexity and large differences in concentrations of the various compounds present, factors which could potentially interfere with the quantification and monitoring of two target analytes, arg-bradykinin and bradykinin. Subsequently, “Heart-cut” 2D LC-electrospray–mass spectrometry (ESI–MS) with post-column on-line standard injection was employed to monitor arg-bradykinin and bradykinin levels as a function of various muscle conditions. The method’s quantification precision was RSD = 3.4% for bradykinin.
Keywords:Column liquid chromatography-mass spectrometry  2D Liquid chromatography  Microdialysis  Peptides  Bradykinin
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号