首页 | 本学科首页   官方微博 | 高级检索  
     检索      

高效液相色谱法测定人血清中5-氟尿嘧啶浓度
引用本文:王冬梅,谢景文.高效液相色谱法测定人血清中5-氟尿嘧啶浓度[J].色谱,1997,15(2):164-165.
作者姓名:王冬梅  谢景文
作者单位:兰州军区总医院!兰州,730050,兰州军区总医院!兰州,730050
摘    要:建立了测定人血清中5-氟尿嘧啶的反相高效液相色谱法。采用ZorbaxODS柱4.6mm×250mm,预柱YWG-C184.6mm×50mm;甲醇:水(20:80)为流动相,紫外检测波长为273um,喃氟啶为内标定量。回收率为96.85%,田间和日内变异系数分别为537%和438%,血清中最低检测浓度为10μg/L。在0.04~50mg/L浓度范围内线性良好,相关系数为0.9990。

关 键 词:5-氟尿嘧啶  高效波相色谱法  人血清  

Determination of 5-Fluorouracil in Human Serum by High Performance Liquid Chromatography
Wang Dongmei and Xie Jingwen.Determination of 5-Fluorouracil in Human Serum by High Performance Liquid Chromatography[J].Chinese Journal of Chromatography,1997,15(2):164-165.
Authors:Wang Dongmei and Xie Jingwen
Institution:General Hospital of Lanzhou Command of PLA., Lanzhou, 730050.
Abstract:A reversed-phase HPLC method is described for determination of 5-fluorouracil in human serum. After being extracted with ethyl acetate 5-fluorouracil was analyzed by reversed-phase HPLC colunln (Zorbax ODS)and UV-detector (273nm)with tegaful as internal standard. The mobile phase was a mixture ot meLnyi alcohol and water(20: 80, V:V ) at a flow rate of lmL/min. The linear range was 0. 04-50mg/L(r = 0. 9990) and the detectable limit was 10ng/mL. The average recovery was 96. 85% and the coefficients of variation were 4. 38% and 5. 37 % for within-day and day-to-day tests respectively.
Keywords:high performance liquid chromatography  5-fluorouracil  human serum
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号