首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Sinopak-s-DEAE高效弱阴离子交换色谱填料的研究
引用本文:何秀娟,吴晓军,乔霞,刘国诠.Sinopak-s-DEAE高效弱阴离子交换色谱填料的研究[J].色谱,1997,15(1):15-17.
作者姓名:何秀娟  吴晓军  乔霞  刘国诠
作者单位:中国科学院化学研究所
摘    要:以多孔硅胶为基质,用改进的合成方法制备了Sinopak-s-DEAE高效弱阴离子交换色谱填。考察了反应条件对填料合成的影响,并以标准蛋白为样品进行了色谱行为的研究,结果表明:所制备的填料对蛋白质的分离性能良好,且对蛋白质的非特异性吸附小。

关 键 词:离子交换色谱法  填料制备  蛋白质
收稿时间:1996-2-20
修稿时间:1996-4-2

Preparation and Characterization of Sinopak s DEAE Weak Anion Exchange Packing for High Performance Liquid Chromatography
He Xiujuan,Wu Xiaojun,Qiao Xia and Liu Guoquan.Preparation and Characterization of Sinopak s DEAE Weak Anion Exchange Packing for High Performance Liquid Chromatography[J].Chinese Journal of Chromatography,1997,15(1):15-17.
Authors:He Xiujuan  Wu Xiaojun  Qiao Xia and Liu Guoquan
Institution:Institute of Chemistry, the Chinese Academy of Sciences, Beijing, 100080.
Abstract:High-performance ion exchange chromatography (HPIEC) is extensively used in the separation of peptides and proteins, especially in the biotechnology process. The principle of separation of proteins is based on the changes of pH and salt concentration in the mobile phase for the chromatographic model. A new synthetic method with the help of a catalyst for the bounding of diethylaminoethyl group on a home-made macro-pore silica sphere (the trade mark is Sinopak-s, with sphere size of 5 microm and pore diameter of 100 nm) was developed in our laboratory for the application of the scale-up separation of biotechnological target products in China. The Sinopak-s-DEAE weak anion ion exchange matrix for HPLC was prepared and characterized with various proteins. The pH value and reaction time were discussed for the reaction efficiency of ligand to the silica sphere. The coverage of the DEAE ligand on the silica surface were among 1.6 to 2.1 micromol/m2 for six batches of packings. The influences of the pH value and the salt concentration in mobile phase upon the retention of proteins on the DEAE column were also discussed. A bio-activity recovery up to 98% for trypsin was arrived after purification with the DEAE column under the chosen chromatographic conditions. The capacity of matrix for BSA was 80 mg/g. The column was successfully applied to separate a mixture of several standard proteins in a linear gradient elution condition from 0 to 0.4 mol/L of NaCl in a 50 mmol/L of Tris/HCl buffer (pH 7.0) at 1.0 mL/min flow rate and detected at 280 nm wavelength.
Keywords:weak anion exchange matrix for high performance liquid chromatography  preparation of stationary phase  protein  
本文献已被 CNKI 维普 等数据库收录!