首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of Colilert-18 for detection and enumeration of fecal coliform bacteria in wastewater using the U.S. Environmental Protection Agency Alternative Test procedure Protocol
Authors:Warden Paul S  DeSarno Monique S  Volk Sarah E  Eldred Bradley J
Affiliation:Analytical Services, Inc., 130 Allen Brook Ln, Williston, VT 05495, USA. pwarden@analyticalservices.com
Abstract:This study compared recovery of fecal coliform bacteria from sewage by Colilert-18 and Standard Methods 9222D (membrane-Fecal Coliform medium) in accordance with the U.S. Environmental Protection Agency (EPA) Alternative Test Protocol (ATP). Samples were collected from 10 different wastewater treatment plants in the northeastern United States and tested in a single laboratory. Twenty replicates of each sample were analyzed by each method, and 200 positive and 200 negative responses were confirmed for each method. Recovery of fecal coliforms by Colilert-18 was significantly higher than (8 of 10 sites) or statistically equivalent to (1 of 10 sites) recovery by the reference method (Standard Methods 9222D) for samples from all but one site. Both methods had low false-positive rates (< 2%); however, the false-negative rate observed with Standard Methods 9222D (21.5%) was substantially higher than that observed with Colilert-18 (7%). The accuracy rates of the two methods were calculated as 96.5 and 88.9% for Colilert-18 and Standard Methods 9222D, respectively. The results of this study demonstrate that Colilert-18 meets the acceptance criteria for alternative methods specified in the EPA ATP.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号