首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Influence of nucleation on the flow boiling heat transfer coefficient of a refrigerant mixture under varied heat flux conditions
Authors:B Raja  D K Kumar  D M Lal  R Saravanan
Institution:(1) College of Engineering, Guindy, Anna University, Chennai, 600 025, Tamil Nadu, India
Abstract:The influence of nucleation on the flow boiling heat transfer coefficient of R-134a/R-290/R-600a refrigerant mixture is experimentally studied in a smooth horizontal tube of 12.7 mm diameter. The heat transfer coefficients are experimentally measured for stratified flow patterns under a varied heat flux condition; a condition found in the evaporator of refrigerators and deep freezers. The experiments are conducted in a counter-current heat exchanger test section. By regulating the flow rate and inlet temperature of acetone, which is the heating fluid flowing in the outer tube, a varied heat flux is provided to the refrigerant flowing in the inner tube. The refrigerant mass flow rate is fixed between 3 and 5 g s−1 and its inlet temperature between −8.59 and 5.33°C, which corresponds to a pressure of 3.2 to 5 bar. The significance of nucleate boiling prevailing in the above-mentioned evaporators is highlighted. The experimental heat transfer coefficients are also compared with well known heat transfer correlations.
Keywords:
本文献已被 SpringerLink 等数据库收录!