首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of itopride in human plasma by liquid chromatography coupled to tandem mass spectrometric detection: application to a bioequivalence study
Authors:Lee Heon-Woo  Seo Ji-Hyung  Choi Seung-Ki  Lee Kyung-Tae
Affiliation:a College of Pharmacy, Kyung Hee University, Hoegi-Dong, Dongdaemun-Ku, Seoul 130-701, Republic of Korea
b Department of Pharmacology, College of Medicine, Pochon Cha University, Kyonggi-Do 463-712, South Korea
Abstract:A simple method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of itopride in human plasma, using sulpiride as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 359.5 > 166.1 for itopride and m/z 342.3 > 111.6 for IS, respectively. Analytes were chromatographed on an YMC C18 reverse-phase chromatographic column by isocratic elution with 1 mM ammonium acetate buffer-methanol (20: 80, v/v; pH 4.0 adjusted with acetic acid). Results were linear (r2 = 0.9999) over the studied range (0.5-1000 ng mL−1) with a total analysis time per run of 2 min for LC-MS/MS. The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers.
Keywords:Itopride   Liquid-liquid extraction   Liquid chromatography/tandem mass spectrometry   Human plasma   Bioequivalence
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏