首页 | 本学科首页   官方微博 | 高级检索  
     检索      

萃取-磷钼蓝比色法测定镍铬丝中磷
引用本文:瞿昕薇.萃取-磷钼蓝比色法测定镍铬丝中磷[J].光谱实验室,2003,20(3):433-435.
作者姓名:瞿昕薇
作者单位:遵义钛厂质量检验中心,贵州省遵义市,563004
摘    要:在0.7—1.0mol/L的硝酸介质中^3],采用萃取-磷钼蓝比色法测定镍铬丝中的磷,络合物的最大吸收峰位于680nm,测定范围为0.001%-0.05%,相对标准偏差为<3.8%。

关 键 词:萃取  磷钼蓝比色法  测定  镍铬丝  
文章编号:1004-8138(2003)03-0433-03
修稿时间:2003年3月14日

Determination of Phosphorus in Nickel-Chromium Wire by the Extraction-Phosphomolybdate Blue Spectrophotometry
QU Xin-Wei.Determination of Phosphorus in Nickel-Chromium Wire by the Extraction-Phosphomolybdate Blue Spectrophotometry[J].Chinese Journal of Spectroscopy Laboratory,2003,20(3):433-435.
Authors:QU Xin-Wei
Abstract:In the medium of 0.7-1.0mol/L HNO 3,phosphorus in nickel-chromium wire was determined by the extraction-phosphomolybdate blue spectrophotometry.The color complex has a maximum absorption at 680nm.The determination range for phosphorus is 0.001%-0.05%.The relative standard deviation is less than 3.8%.
Keywords:Extraction-Phosphomolybdate Blue Spectrophotometry  Nickel-Chromium Wire  Phosphorus    