Theoretical Analysis of a Capillary Tube Interferometer
YANG Ai-ling,ZHAN Jin-liang,LI Wen-dong.Theoretical Analysis of a Capillary Tube Interferometer[J].Acta Photonica Sinica,2008,37(10):2048-2053.
Authors:YANG Ai-ling  ZHAN Jin-liang  LI Wen-dong
Institution:YANG Ai-ling a,b,ZHAN Jin-liang a,LI Wen-dong a(a.College of Information Science & Engineering,b.College of Marine Geo-science,Ocean University of China,Qingdao,Sh,ong 266100,China)
Abstract:Geometrical optical analysis of a capillary tube interferometer was presented. The optical path length (OPL) was deduced from a cylindrical lens to a screen. Ray tracing and simulating of the capillary tube interferometer was presented. The results show that the fringe pattern produced by the capillary tube interferometer can be explained by two-beam interference. Two rays coming from two different positions on the cylindrical lens may have the same OPL. And, two rays coming from two different positions on the cylindrical lens may get to the same point on the screen. When the interference condition matches, the interferogram will be formed. A computer program to simulate the interference fringe pattern was established. The influences caused by the refractive indices of the liquids in the capillary tube, the outer and inner radii of the capillary tubes were given by computer simulation. This simulation shows that a capillary tube with thin wall should be used in experiment and the fringe pattern is very sensitive to the distance between the cylindrical lens and the capillary tube. For enhancing accuracy, this distance should be determined by fitting a standard liquid with known refractive index in experiment.
Keywords:Capillary tube interferometer  Ray tracing  Refractive indices of liquids  Two-beam interference