首页 | 本学科首页   官方微博 | 高级检索  
     检索      

SUNIST装置中磁探针出气率测量
引用本文:张璐,曾龙,谭熠,谢丽风,高喆,王文浩.SUNIST装置中磁探针出气率测量[J].核聚变与等离子体物理,2010,30(3):277-280.
作者姓名:张璐  曾龙  谭熠  谢丽风  高喆  王文浩
作者单位:(清华大学工程物理系,北京 100084)
基金项目:国家自然科学基金资助项目(10535020);973项目(2008CB717804)
摘    要:通过出气率测量装置评价了SUNIST装置的内部磁探针出气特性,实验结果表明其出气量和出气气体成分不足以影响SUNIST真空特性。其后的放电实验验证了这一结论。

关 键 词:出气率  磁探针  小孔流导法  球形托卡马克  
收稿时间:2009-09-22

Measurement of outgassing rate of magnetic probe in the SUNIST spherical tokamak
ZHANG Lu,ZENG Long,TAN Yi,XIE Li-feng,GAO Zhe,WANG Wen-hao.Measurement of outgassing rate of magnetic probe in the SUNIST spherical tokamak[J].Nuclear Fusion and Plasma Physics,2010,30(3):277-280.
Authors:ZHANG Lu  ZENG Long  TAN Yi  XIE Li-feng  GAO Zhe  WANG Wen-hao
Institution:(Department of Engineering Physics, Tsinghua University, Beijing 100084)
Abstract:The outgassing characters of probes installed inside the SUNIST vessel are evaluated by the device for measuring outgassing rate. The results show the influence isn’t important to the vacuum of SUNIST spherical tokamak. The discharging experiment supports this issue.
Keywords:Outgassing rate  Magnetic probe  Eyelet conductance method  Spherical tokamak  