Comparison of X-ray source concepts for radiographic purposes at OMEGA |
| |
Authors: | L. Jacquet M. Primout B. Villette F. Girard G. Oudot |
| |
Affiliation: | CEA, DAM, DIF, F-91297 Arpajon, France |
| |
Abstract: | As multi-keV X-ray sources, seven targets including thick and thin foils, metal-lined halfraums and a foil combined with a plastic cylinder, have been shot on Omega in September 2011. Titanium was used as X-ray emitting material for all the sources. Using experimental data and FCI2 simulation results, we have, for each source type, characterized the emission lobes and determined the spatial directions of maximum multi-keV energy. These results demonstrate the benefit of using a laser drive with a pre-pulse for both thick and thin foils. The favorable effect of a confinement cylinder for the X-ray emitted from front side by a thin foil has also been experimentally found but is not yet confirmed by the simulations. The temporal waveforms of the X-ray power obtained from the different sources as well as the emission spots at the times of maximum emission are also compared. |
| |
Keywords: | X-ray sources Radiography Omega laser Titanium |
本文献已被 ScienceDirect 等数据库收录! |
|