首页 | 本学科首页   官方微博 | 高级检索  
     


LC–MS–MS Development and Validation for Simultaneous Quantitation of Metformin,Glimepiride and Pioglitazone in Human Plasma and Its Application to a Bioequivalence Study
Authors:Sengupta  Pinaki  Bhaumik  Uttam  Ghosh  Animesh  Sarkar  Amlan Kanti  Chatterjee   Bappaditya  Bose   Anirbandeep  Pal   Tapan Kumar
Affiliation:1.Department of Pharmaceutical Technology, Bioequivalence Study Centre, Jadavpur University, Kolkata, 700 032, India
;
Abstract:

A simple, precise and reproducible liquid chromatography–tandem mass spectrometry method has been developed and validated according to the Food and Drug Administration guidelines for the simultaneous quantitation of antidiabetic drugs metformin, glimiperide and pioglitazone in human plasma using glipizide as an internal standard. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization technique, operating in multiple reaction monitoring and positive ion mode. Inter-batch and intra-batch coefficient of variation across four validation runs for the quality control samples was less than 7%. The accuracy determined at quality control levels was within 92.81–105.13%. The method was applied to a bioequivalence study.

Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏