首页 | 本学科首页   官方微博 | 高级检索  
     


A novel reagentless glutamate microband biosensor for real-time cell toxicity monitoring
Authors:G. Hughes  R.M. Pemberton  P.R. Fielden  J.P. Hart
Affiliation:1. Centre for Research in Biosciences, Faculty of Health and Applied Sciences, University of the West of England, Bristol, Coldharbour Lane, Bristol, BS16 1QY, United Kingdom;2. Department of Chemistry, Lancaster University, Bailrigg, Lancaster, LA1 4YB, United Kingdom
Abstract:A reagentless glutamate biosensor was applied to the determination of glutamate released from liver hepatocellular carcinoma cells (HepG2) in response to toxic challenge from various concentrations of paracetamol. A screen printed carbon electrode (SPCE) containing the electrocatalyst Meldola's Blue (MB-SPCE) served as the electron mediator for the oxidation of NADH.
Keywords:Glutamate   Microband   Biosensor   Cell toxicity   Amperometric   HepG2
本文献已被 ScienceDirect 等数据库收录!