首页 | 本学科首页   官方微博 | 高级检索  
     


Investigation of the “true” extraction recovery of analytes from multiple types of tissues and its impact on tissue bioanalysis using two model compounds
Authors:Long Yuan,Li Ma,Lisa Dillon,R. Marcus Fancher,Huadong Sun,Mingshe Zhu,Lois Lehman-McKeeman,Anne-Franç  oise Aubry,Qin C. Ji
Affiliation:1. Bioanalytical Sciences, Research & Development, Bristol-Myers Squibb, Princeton, NJ 08543, USA;2. Biotransformation, Research & Development, Bristol-Myers Squibb, Princeton, NJ 08543, USA;3. Discovery Toxicology, Research & Development, Bristol-Myers Squibb, Princeton, NJ 08543, USA;4. Metabolism and Pharmacokinetics, Research & Development, Bristol-Myers Squibb, Princeton, NJ 08543, USA
Abstract:LC-MS/MS has been widely applied to the quantitative analysis of tissue samples. However, one key remaining issue is that the extraction recovery of analyte from spiked tissue calibration standard and quality control samples (QCs) may not accurately represent the “true” recovery of analyte from incurred tissue samples. This may affect the accuracy of LC-MS/MS tissue bioanalysis. Here, we investigated whether the recovery determined using tissue QCs by LC-MS/MS can accurately represent the “true” recovery from incurred tissue samples using two model compounds: BMS-986104, a S1P1 receptor modulator drug candidate, and its phosphate metabolite, BMS-986104-P. We first developed a novel acid and surfactant assisted protein precipitation method for the extraction of BMS-986104 and BMS-986104-P from rat tissues, and determined their recoveries using tissue QCs by LC-MS/MS. We then used radioactive incurred samples from rats dosed with 3H-labeled BMS-986104 to determine the absolute total radioactivity recovery in six different tissues. The recoveries determined using tissue QCs and incurred samples matched with each other very well. The results demonstrated that, in this assay, tissue QCs accurately represented the incurred tissue samples to determine the “true” recovery, and LC-MS/MS assay was accurate for tissue bioanalysis. Another aspect we investigated is how the tissue QCs should be prepared to better represent the incurred tissue samples. We compared two different QC preparation methods (analyte spiked in tissue homogenates or in intact tissues) and demonstrated that the two methods had no significant difference when a good sample preparation was in place. The developed assay showed excellent accuracy and precision, and was successfully applied to the quantitative determination of BMS-986104 and BMS-986104-P in tissues in a rat toxicology study.
Keywords:Tissue bioanalysis   LC-MS/MS   Extraction recovery   Radioactive incurred samples   QC in tissue homogenate   Intact tissue QC
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号