摘    要:改进了利用荧光分光光度计测定水质石油类样品的分析方法.水质石油样品采用正己烷提取,经硅酸镁净化后使用荧光分光光度计检测.经过优化,方法曲线线性在0.999以上,检出限为0.007 mg/L.经过3种地表水、1种地下水以及2种工业废水的验证,回收率为87.5%~110.0%.分别使用紫外法、红外法与荧光光度法进行比对,地...

关 键 词:水质  石油类  荧光光度法
收稿时间:2020-12-09

Optimization of Determination of Petroleum Samples in Surface Water,Groundwater and Wastewater by Fluorescence Spectrophotometry
Institution:Ecology and Environmental Monitoring Center of Xinjiang, Urumqi 830011, China
Abstract:The analytical method for the determination of petroleum samples in water by fluorescence spectrophotometry was improved. The petroleum samples in water was extracted with n-hexane, purified by magnesium silicate, and detected using a fluorescence spectrophotometer. Under optimal conditions, the calibration curve of the method showed good linearity, the correlation coefficient was 0.999, and the detection limit was 0.007 mg/L. The method has been applied to determinate petroleum samples collected from different factory surface water and groundwater. The average spiked recoveries were among 87.5%~110.0%. Comparing ultraviolet and infrared methods with fluorescence spectrophotometry, the relative deviation of surface water and groundwater was 5.3%~13.3%, and the wastewater was 1.7%~19.5%. The improved method is accurate and sensitive, and can be used as a supplement, to the petroleum samples in water monitoring standard system.