Anion-exchange chromatography of normal and monoclonal serum immunoglobulins |
| |
Authors: | P Gallo A Sidén B Tavolato |
| |
Affiliation: | Division of Analytical Chemistry, Leiden University, The Netherlands. |
| |
Abstract: | Anion-exchange chromatography was used for separations of the three main immunoglobulin classes in human sera. The material included normal sera as well as sera with monoclonal immunoglobulin components. The Mono Q anion-exchange column was eluted with a stepwise gradient formed by 0.05 and 0.3 M phosphate buffers. No indications of negative effects on the sample components were observed and the protein recovery was high. A fast, easy and reproducible separation of immunoglobulins G, A and M was obtained. |
| |
Keywords: | |
|
|