首页 | 本学科首页   官方微博 | 高级检索  
     


A technique for the determination of ruthenium stable isotopes in urine samples
Authors:I. Veronese  M. C. Cantone  A. Giussani  A. Arogunjo  P. Roth  V. Höllriegl  U. Oeh  U. Holzwarth  K. Abbas
Affiliation:1.Dipartimento di Fisica,Università degli Studi di Milano,Italy;2.Sezione di Milano,INFN,Milano,Italy;3.Institute of Radiation Protection,GSF, National Research Center for Environment and Health,Neuherberg,Germany;4.Institute for Health and Consumer Protection,Joint Research Centre of the European Commission,Ispra (Va),Italy
Abstract:Proton activation analysis has been recently applied for the determination of stable isotopes of trace metals in blood plasma samples taken from volunteers during tracer kinetic studies. The very low values of intestinal uptake for some elements, like ruthenium, make the kinetics of the excretion crucial for interpreting the bioassay data. Therefore, a procedure has been developed to process urine samples in order to have proper targets for the activation with protons. Preliminary tests with Ru-doped samples, conducted using the MC-40 Cyclotron at JRC Ispra, has confirmed the feasibility of the method. The minimum detectable concentrations, in the current operating conditions, are 16 ng 99Ru·ml−1 and 0.5 ng 101Ru·ml−1. On leave from the Federal University of Technology, Akure, Nigeria.
Keywords:
本文献已被 SpringerLink 等数据库收录!