Single-ended mid-infrared laser-absorption sensor for time-resolved measurements of water concentration and temperature within the annulus of a rotating detonation engine |
| |
Authors: | Séan J. Cassady Christopher L. Strand Christopher S. Goldenstein R. Mitchell Spearrin Christopher M. Brophy Jay B. Jeffries Ronald K. Hanson |
| |
Affiliation: | 1. Department of Mechanical Engineering, Thermosciences Division, 452 Escondido Mall, Stanford University, California 94305, USA;2. School of Mechanical Engineering, Purdue University, West Lafayette, Indiana 47907, USA;3. Department of Mechanical and Aerospace Engineering, University of California, Los Angeles, California 90095, USA;4. Department of Mechanical and Aerospace Engineering, Naval Postgraduate School, Monterey, California 93943, USA |
| |
Abstract: | A novel single-ended mid-infrared laser-absorption sensor for time-resolved measurements of water mole fraction and temperature was developed and deployed within the annulus of a hydrogen/air-fed rotating detonation engine (RDE). The sensor transmitted two laser beams targeting mid-infrared water transitions through a single optical port on the outer wall of the cylindrical RDE annulus and measured the backscattered radiation from the RDE inner surface using a photodetector for a round-trip path of 1.52?cm. Optimizing the sensor's optical arrangement using numerical ray tracing to minimize interference from optical emission, beam steering, and scattered laser light from window surfaces was essential to sensor performance. Scanned-wavelength-modulation spectroscopy with second-harmonic detection and first-harmonic normalization was implemented to allow for frequency-domain multiplexing of the two lasers and to suppress non-absorbing interference sources such as beam-steering and emission. Tunable diode lasers near 2551 and 2482?nm were modulated at 100 and 122?kHz, respectively, and sinusoidally scanned across the peaks of their respective water transitions at 10?kHz to provide a measurement rate of 20?kHz and detection limit of 0.5% water by mole. Experimentally derived spectroscopic parameters enabled water and temperature sensing with respective uncertainties of 7.3% and 5.3% relative to the measured values. Time-resolved and time-averaged sensor measurements of gas temperature and water vapor mole fraction allow quantitative evaluation of the combustion progress at the measurement location and thus provide a design tool for RDE optimization. Broadly, this single-ended laser sensor should find applications in other combustion systems where optical access is limited. |
| |
Keywords: | Single-ended Combustion diagnostics Mid-infrared Wavelength-modulation spectroscopy Detonations |
本文献已被 ScienceDirect 等数据库收录! |
|