首页 | 本学科首页   官方微博 | 高级检索  
     


Change of evaporation rate of single monocomponent droplet with temperature using time-resolved phase rainbow refractometry
Authors:Yingchun Wu  Haipeng Li  Xuecheng Wu  Gérard Gréhan  Lutz Mädler  Cyril Crua
Affiliation:1. State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China;2. Advanced Engineering Centre, University of Brighton, Brighton BN2 4GJ, UK;3. Leibniz Institute for Materials Engineering IWT, Faculty of Production Engineering, University of Bremen, Bremen 28359, Germany;4. CNRS UMR 6614/CORIA, BP12, Saint Etienne du Rouvray, 76801, France
Abstract:
Droplet evaporation characterization, although of great significance, is still challenging. The recently developed phase rainbow refractometry (PRR) is proposed as an approach to measuring the droplet temperature, size as well as evaporation rate simultaneously, and is applied to a single flowing n-heptane droplet produced by a droplet-on-demand generator. The changes of droplet temperature and evaporation rate after a transient spark heating are reflected in the time-resolved PRR image. Results show that droplet evaporation rate increases with temperature, from ?1.28×10?8 m2/s at atmospheric 293 K to a range of (?1.5, ?8)×10?8 m2/s when heated to (294, 315) K, agreeing well with the Maxwell and Stefan–Fuchs model predictions. Uncertainty analysis suggests that the main source is the indeterminate gradient inside droplet, resulting in an underestimation of droplet temperature and evaporation rate. With the demonstration on simultaneous measurements of droplet refractive index as well as droplet transient and local evaporation rate in this work, PRR is a promising tool to investigate single droplet evaporation in real engine conditions.
Keywords:Phase rainbow refractometry  Droplet  Size change  Temperature  Evaporation rate
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号