摘    要:我台广播设备数字化改造已经多年,改造核心设备AEQ数字调音台等由于使用年限增加故障率也逐年上升,对于广播安全播出是重大的隐患。针对AEQ调音台故障特点,探索出AEQ数字调音台的维修方法以及改进之处,并设计开发基于物联网技术对调音台等重要数字设备多点实时监测系统。

关 键 词:AEQ  DC-DC模块  Zigbee  报警
收稿时间:2015/4/12 0:00:00
修稿时间:2015/4/12 0:00:00

AEQ digital mixer maintenance and temperature monitoring system
chenshuai.AEQ digital mixer maintenance and temperature monitoring system[J].Audio Engineering,2015,39(9).
Authors:chenshuai
Institution:Jiangxi radio and Television
Abstract:I have for many years, digitization of radio equipment reform core equipment AEQ digital mixer etc. Due to the use fixed number of year increase the failure rate is rising year by year, is significant for broadcast safe hidden trouble. In AEQ mixer fault characteristics, explore AEQ maintenance method of digital mixer and improvements, and design and development based on Internet of things technology for mixer important digital devices such as multipoint real-time monitoring system.
Keywords:AEQ  DC - DC  module  Zigbee  Alarm