首页 | 本学科首页   官方微博 | 高级检索  
     检索      


The sterilization of Escherichia coli by dielectric-barrier discharge plasma at atmospheric pressure
Authors:Hu Miao  Guo Yun
Institution:College of Nuclear Science and Technology, Harbin Engineering University, Harbin 150001, China
Abstract:The sterilization of E. coli (ATCC8099) using an atmospheric pressure, air DBD plasma driven by 100 Hz high-voltage power supply was investigated in this paper. The results showed that germicidal efficiency was closely related to the plasma treatment time, the gap spacing, the initial cell density and the surface characters of substrate materials. The germicidal efficiency was 99.999% under the conditions of 5-min plasma treatment, 3-cm gap spacing and on PET films. After plasma exposure for 5 min, the temperature was observed below 43 °C which could not lead to inactivate E. coli. The observation of protein leakage and cell morphology alteration by transmission electron microscopy (TEM) techniques revealed that the etching action on cell membrane by electrons, ions and radicals was primary reason of DBD air plasma sterilization.
Keywords:Plasma  DBD  Escherichia coli  Sterilization
本文献已被 ScienceDirect 等数据库收录!