摘    要:阐述了血样经过KMnO4分解后,在HCl-VC-Hg^2+介质中,采用动态微分电位溶出法,利用标准工作曲线法定量测定血铅的方法。

关 键 词:    动态微分电位溶出法  测定  中毒
修稿时间:1999-07-12

DETERMINATION OF LEAD IN BLOOD BY THE KINETIC DIFFERENTIAL POTENTIOMETRIC STRIPPING METHOD
Xie Weiping,Ha Guilian,Huang Yingyu.DETERMINATION OF LEAD IN BLOOD BY THE KINETIC DIFFERENTIAL POTENTIOMETRIC STRIPPING METHOD[J].Physical Testing and Chemical Analysis Part B:Chemical Analgsis,2000,36(7):307-308.
Authors:Xie Weiping  Ha Guilian  Huang Yingyu
Institution:Xie Weiping ,Ha Guilian ,Huang Yingyu ; (Qtanzhuo Municipal Sanitation and Antiepidemic Station Quanzhou 362000)
Abstract:It is proposed that the blood sample is treated by oxidation with KMnO 4, and its lead content is determined in a medium containing HCl, Hg 2 and VC. by the kinetic differential potentiometric stripping method. The results are obtained from the standard working curve.