首页 | 本学科首页   官方微博 | 高级检索  
     


Correcting movement errors in frequency-sweeping interferometry
Authors:Swinkels B L  Bhattacharya N  Braat J J M
Affiliation:Optics Research Group, Delft University of Technology, Lorentzweg 1, 2628 Cl, Delft, The Netherlands. b.l.swinkels@tnw.tudelft.nl
Abstract:Absolute distance measurements can be performed with an interferometric method that uses only a single tunable laser. This method has one major drawback, because a small target movement of the order of one wavelength during a measurement will be interpreted as a movement of one synthetic wavelength. This effect is usually mitigated by adding a second (nonscanning) laser. We show that absolute distance measurements can be performed with only one laser if the movements encountered are smooth, on the time scale of one measurement. In this case the movement errors can be compensated with a simple algorithm that combines several subsequent measurements. First experimental results show good agreement with theory.
Keywords:
本文献已被 PubMed 等数据库收录!