首页 | 本学科首页   官方微博 | 高级检索  
     检索      


3D printed titanium micro-bore columns containing polymer monoliths for reversed-phase liquid chromatography
Authors:Vipul Gupta  Mohammad Talebi  Jeremy Deverell  Sara Sandron  Pavel N Nesterenko  Brendan Heery  Fletcher Thompson  Stephen Beirne  Gordon G Wallace  Brett Paull
Institution:1. Australian Centre for Research on Separation Sciences (ACROSS), School of Physical Sciences, University of Tasmania, Sandy Bay, Hobart 7001, Tasmania, Australia;2. ARC Centre of Excellence for Electromaterials Science, School of Physical Sciences, University of Tasmania, Sandy Bay, Hobart 7001, Tasmania, Australia;3. ARC Centre of Excellence for Electromaterials Science, Intelligent Polymer Research Institute, University of Wollongong, NSW 2522, Australia
Abstract:The potential of 3D selective laser melting (SLM) technology to produce compact, temperature and pressure stable titanium alloy chromatographic columns is explored. A micro bore channel (0.9 mm I.D. × 600 mm long) was produced within a 5 × 30 × 30 mm titanium alloy (Ti–6Al–4V) cuboid, in form of a double handed spiral. A poly(butyl methacrylate-co-ethyleneglycoldimethacrylate) (BuMA-co-EDMA) monolithic stationary phase was thermally polymerised within the channel for application in reversed-phase high-performance liquid chromatography. The prepared monolithic column was applied to the liquid chromatographic separation of intact proteins and peptides. Peak capacities of 69–76 (for 6–8 proteins respectively) were observed during isothermal separation of proteins at 44 °C which were further increased to 73–77 using a thermal step gradient with programmed temperature from 60 °C to 35 °C using an in-house built direct-contact heater/cooler platform based upon matching sized Peltier thermoelectric modules. Rapid temperature gradients were possible due to direct-contact between the planar metal column and the Peltier module, and the high thermal conductivity of the titanium column as compared to a similar stainless steel printed column. The separation of peptides released from a digestion of E.coli was also achieved in less than 35 min with ca. 40 distinguishable peaks at 210 nm.
Keywords:3D SLM titanium alloy printing  Peltier thermoelectric heating/cooling module  Bidirectional temperature control  Step thermal gradient  Chip based chromatographic column  Poly(BuMA-co-EDMA) monolith
本文献已被 ScienceDirect 等数据库收录!