十二烷基苯磺酸钠-盐酸苯海索-Ru(bpy)2+3体系的电化学发光行为研究及应用
引用本文:李利军,邓春燕,高文燕,吴美艳,胡大春,黄文艺,李彦清.十二烷基苯磺酸钠-盐酸苯海索-Ru(bpy)2+3体系的电化学发光行为研究及应用[J].分析测试学报,2012,31(2):216-220.
作者姓名:李利军  邓春燕  高文燕  吴美艳  胡大春  黄文艺  李彦清
作者单位:1.广西工学院生物与化学工程系;2.广西大学化学与化学工程学院
基金项目:国家自然科学基金资助项目(20665001);广西科学基金资助项目(0832062)
摘    要:在十二烷基苯磺酸钠(SDBS)存在下,考察了盐酸苯海索(BH)-Ru(bpy)32+体系的电化学及其发光行为。结果表明,BH对Ru(bpy)32+体系的电化学发光具有增敏效应;在SDBS存在下,BH对Ru(bpy)32+体系电化学发光的增敏效应显著增强,发光强度提高约16倍。据此建立了一种高效、简便的BH电化学发光新方法。在最佳实验条件下,BH的浓度在4.0×10-7~1.0×10-4 mol/L范围内与相对发光强度呈线性关系(r=0.995 5),检出限(S/N=3)为1.11×10-9 mol/L;连续平行测定1.0×10-5 mol/L BH溶液10次,发光强度的RSD为3.2%。样品的回收率为96%~108%,RSD为4.3%。该方法样品前处理简单,具有较高的选择性和灵敏度,用于实际样品中BH的测定,结果满意。

关 键 词:盐酸苯海索  十二烷基苯磺酸钠  联吡啶钌  电化学发光

Determination of Benzhexol Hydrochloride by Electrochemiluminescence in the Presence of Sodium Dodecyl Benzene Sulfonate
LI Li-jun,DENG Chun-yan,GAO Wen-yan,WU Mei-yan,HU Da-chun,HUANG Wen-yi,LI Yan-qing.Determination of Benzhexol Hydrochloride by Electrochemiluminescence in the Presence of Sodium Dodecyl Benzene Sulfonate[J].Journal of Instrumental Analysis,2012,31(2):216-220.
Authors:LI Li-jun  DENG Chun-yan  GAO Wen-yan  WU Mei-yan  HU Da-chun  HUANG Wen-yi  LI Yan-qing
Institution:1(1.Department of Biological and Chemical Engineering,Guangxi University of Technology,Liuzhou 545006,China; 2.College of Chemistry and Chemical Engineering,Guangxi University,Nanning 530004,China)
Abstract:In the presence of sodium dodecyl benzene sulfonate(SDBS),the electrochemical and electrochemiluminescence(ECL) characteristics of the Ru(bpy)2+3- benzhexol hydrochloride(BH) system at Au electrode were studied by ECL and cyclic voltammetric(CV) method.The results showed that the ECL intensity of Ru(bpy)2+3 at Au electrode was enhanced significantly in the presence of BH.In the presence of SDBS,the ECL intensity of Ru(bpy)2+3- benzhexol hydrochloride system was enhanced about 16 times.Based on this,a new electrochemiluminescence method was established for the determination of BH.Under the optimum condition,the enhanced ECL intensity had a good linear relationship with the concentration of BH in the range of 4.0×10-7-1.0×10-4 mol/L,with a detection limit of 1.11×10-9 mol/L.The RSD(n=10) of ECL intensities for the determinations of 1.0×10-5 mol/L BH were 3.2%.The recoveries for the samples were between 96% and 108% with RSD of 4.3%.With high selectivity and sensitivity,this proposed method was applied in the determination of BH in real sample with satisfactory results.
Keywords:benzhexol hydrochloride  sodium dodecyl benzene sulfonate(SDBS)  Ru(bpy)2+3  electrochemiluminescence