首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Improved acceleration of phase-contrast flow imaging with magnitude difference regularization
Institution:1. Department of Radiology, New York Presbyterian — Columbia University Medical Center, 622 W 168th St, PH1-317, New York, NY 10032, United States;2. Department of Radiology, Beth Israel Deaconess Medical Center, One Deaconess Road, Boston, MA 02215, United States;3. Department of Surgery, New York Presbyterian-Weill-Cornell, 525 East 68th Street Starr 8, New York, NY 10065, United States
Abstract:PurposeTo develop a regularized image reconstruction algorithm for improved scan acceleration of phase-contrast (PC) flow MRI.MethodsBased on the magnitude similarity between bipolar-encoded k-space data, magnitude-difference regularization was incorporated into the conventional compressed sensing (CS) reconstruction. The gradient of the magnitude regularization was derived so the reconstruction problem can be solved using non-linear conjugate gradient with backtracking line search. Phase contrast flow data obtained in the peripheral arteries of healthy and patient subjects were retrospectively undersampled for testing the proposed reconstruction method. Three-dimensional velocity-encoded PC flow MRI was performed with prospective 4-fold undersampling for measuring arotic flow velocity in a healthy volunteer.ResultsIn the femoral arteries of healthy volunteers, the root-mean-square (RMS) errors of mean velocities were 0.56 ± 0.09 cm/s with CS-only reconstruction and 0.46 ± 0.08 cm/s with addition of magnitude regularization for three-fold acceleration; 1.34 ± 0.17 cm/s (CS only) and 1.08 ± 0.15 cm/s (magnitude regularized) for four-fold acceleration. In the iliac arteries of the patient, the RMS errors of mean velocities were 0.72 ± 0.12 cm/s and 0.56 ± 0.10 for three-fold acceleration, and 1.75 ± 0.21 and 1.24 ± 0.19 cm/s for four-fold acceleration (in the order of CS-only and magnitude regularized reconstructions). In the popliteal arteries, the RMS errors were 0.61 ± 0.10 cm/s and 0.42 ± 0.11 for three-fold acceleration, and 1.41 ± 0.19 and 1.12 ± 0.17 cm/s for four-fold acceleration. The maximum through-plane mean flow velocities were measured as 63.2 cm/s and 84.5 cm/s in ascending and descending aortas, respectively.ConclusionThe addition of magnitude-difference regularization into conventional CS reconstruction improves the accuracy of image reconstruction using highly undersampled phase-contrast flow MR data.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号